Title
The MRCAT insertion device beamline at the advanced photon source
Document Type
Conference Proceeding
Publication Date
6-6-2000
Abstract
© 2000 American Institute of Physics Inc.. All rights reserved. The Materials Research Collaborative Access Team (MRCAT) beamline 10-ID at the Advanced Photon Source has been in Commisioning since January 1998. This Beamline has been designed as a flexible spectroscopy, scattering, and diffraction facility for the study of materials in situ. Over 70 users have performed experiments at the beamline during this period. Details about the beamline layout, components, performance and configuration for typical experiments will be presented.
Publication Source (Journal or Book title)
AIP Conference Proceedings
First Page
419
Last Page
422
Recommended Citation
Segre, C., Leyarovska, N., Chapman, L., Lavender, W., Plag, P., King, A., Kropf, A., Bunker, B., Kemner, K., Dutta, P., Duran, R., & Kaduk, J. (2000). The MRCAT insertion device beamline at the advanced photon source. AIP Conference Proceedings, 521, 419-422. https://doi.org/10.1063/1.1291825