Identifier

etd-04082009-113609

Degree

Master of Science (MS)

Department

Animal Science (Animal, Dairy, and Poultry Sciences)

Document Type

Thesis

Abstract

Transgene expression in stably transgenic organisms is affected by many factors, including the copy number of the transgene in the genome, and by interactions between the transgene and flanking DNA sequences. Transgene copy number has also been shown to effect genetic stability in transgenic plants. Two commonly used methods for transfecting cells are liposome mediated transfection and electroporation. Little is known about the mean transgene copy number or variability of the copy number with these techniques. Quantitative PCR (Q-PCR) has been shown to be an effective method for determining transgene copy number. The objective of this study was to determine transgene copy number after liposome mediated transfection and electroporation. The mean transgene copy number and variability between individual integration events have been determined. Q-PCR conditions were optimized for primer annealing temperature and concentration when amplifying a region of the plasmid hEFGFP used for transfection. The quantitative nature of the Q-PCR reaction was confirmed by amplifying 10-fold dilutions of the plasmid and plotting the threshold cycle (CT) value against the log of the plasmid concentration. A correlation coefficient of 1.00 and a calculated PCR efficiency of 93.3% were obtained from this analysis. Caprine fibroblasts were transfected by electroporation or FuGENE® HD reagent with either a circular or linearized hEFGFP plasmid and plated at low density in medium containing Geneticin®. After 10 days of culture, single cell colonies were isolated and expanded. When cultures reached 1-2 million cells, genomic DNA was isolated. Transgene copy number was determined by amplifying genomic DNA from individual clones representing 1x105 cells with Q-PCR. Transgene copy number was calculated by comparing CT values to a standard curve. The transgene copy number for electroporation circular was 2.7  0.75 (n=32) and 1.3  0.65 (n=19) when using a linear DNA construct. FuGENE® HD using a circular plasmid construct generated a gene copy number of 0.5  0.11 (n=14) and 0.64  0.13 (n=16) for the linear plasmid construct. There were significant differences when comparing electroporation circular to all other treatments, however, there were no differences when comparing electroporation linear, FuGENE® HD circular and FuGENE® HD linear to each other.

Date

2009

Document Availability at the Time of Submission

Release the entire work immediately for access worldwide.

Committee Chair

Dr. Kenneth Bondioli

DOI

10.31390/gradschool_theses.826

Share

COinS